Reference Substances and Infrared Reference Spectra for Pharmacopoeial Analysis (WHO Technical Report Series, No. 885, 1999: Annex 3)
(1999; 117 pages)
Table des matières
Afficher le documentPreface1
Ouvrir ce répertoire et afficher son contenu1. Compilation of national, regional and international reference substances and infrared reference spectra
Fermer ce répertoire2. General guidelines for the establishment, maintenance and distribution of chemical reference substances - Reprint from WHO Technical Report Series, No. 885, 1999: Annex 3
Afficher le documentIntroduction
Fermer ce répertoirePart A. Primary chemical reference substances
Afficher le document1. Assessment of need for the establishment of chemical reference substances
Afficher le document2. Obtaining source material
Ouvrir ce répertoire et afficher son contenu3. Evaluation of chemical reference substances
Fermer ce répertoire4. Chemical and physical methods used in evaluating chemical reference substances
Afficher le document4.1 Methods used to verify the identity of chemical reference substances
Ouvrir ce répertoire et afficher son contenu4.2 Methods used to determine the purity of chemical reference substances
Afficher le document5. Assignment of content
Ouvrir ce répertoire et afficher son contenu6. Handling and distribution of chemical reference substances
Afficher le documentPart B. Secondary chemical reference substances
Afficher le documentReferences
Afficher le documentBack cover
 
4.1 Methods used to verify the identity of chemical reference substances

Where a proposed substance consists of a compound whose structure has been satisfactorily defined, its identity may be confirmed by matching the IR spectra of the substance to that of an authentic compound. Particular care should be taken when polymorphism exists (7). Other highly specific techniques, such as NMR spectroscopy, MS, or X-ray diffraction crystallography, may also be used for such comparisons. The identity of a substance that is intended to replace an established chemical reference substance of the same molecular constitution must be verified, to determine that the characteristic properties of the two specimens are identical. For this purpose it is often sufficient to compare their IR absorption spectra.

However, where no authentic specimen of the proposed substance is available for comparison, and definitive data about its properties are lacking, it may be necessary to verify its identity by applying several analytical techniques currently used to characterize new compounds. Such analytical methods may include elemental analyses, crystallographic studies, MS, NMR spectroscopy, functional group analyses, and IR or UV spectrophotometry, as well as other supplementary tests as required to establish that the proposed substance is fully characterized.