Marketing Authorization of Pharmaceutical Products with Special Reference to Multisource (Generic) Products: A Manual for Drug Regulatory Authorities - Regulatory Support Series No. 005
(1998; 213 pages)
Table of Contents
View the documentPREFACE
View the documentI. INTRODUCTION
Open this folder and view contentsII. PROVISIONS AND PREREQUISITES FOR REGULATORY CONTROL
Open this folder and view contentsIII. OPERATING ACTIVITIES
Open this folder and view contentsIV. REVIEW OF APPLICATIONS FOR MARKETING AUTHORIZATION OF MULTISOURCE (GENERIC) PHARMACEUTICAL PRODUCTS
View the documentV. ISSUE OF WRITTEN MARKETING AUTHORIZATION
View the documentVI. VARIATIONS
View the documentVII. PERIODIC REVIEWS
View the documentVIII. SUSPENSION AND REVOCATION OF MARKETING AUTHORIZATION
View the documentGLOSSARY
View the documentABBREVIATIONS
View the documentREFERENCES
Close this folderANNEXES
Open this folder and view contentsAnnex 1: National drug regulatory legislation: guiding principles for small drug regulatory authorities1
Open this folder and view contentsAnnex 2: *Guidelines for Implementation of the WHO Certification Scheme on the Quality of Pharmaceutical Products Moving in International Commerce1
Close this folderAnnex 3: *Multisource (Generic) Pharmaceutical Products: Guidelines on Registration Requirements to Establish Interchangeability1
View the documentIntroduction
View the documentGlossary
Open this folder and view contentsPart One. Regulatory assessment of interchangeable multisource Pharmaceutical products
Open this folder and view contentsPart Two. Equivalence studies needed for marketing authorization
Close this folderPart Three. Tests for equivalence
Open this folder and view contents10. Bioequivalence studies in humans
View the document11. Pharmacodynamic studies
View the document12. Clinical trials
View the document13. In vitro dissolution
View the documentPart Four. In vitro dissolution tests in product development and quality control
View the documentPart Five. Clinically important variations in bioavailability leading to non-approval of the product
View the documentPart Six. Studies needed to support new post-marketing manufacturing conditions
View the documentPart Seven. Choice of reference product
View the documentAuthors
View the documentReferences
View the documentAppendix 1. Examples of national requirements for in vivo equivalence studies for drugs included in the WHO Model List of Essential Drugs (Canada, Germany and the USA, August 1994)
View the documentAppendix 2. Explanation of symbols used in the design of bioequivalence studies in humans, and commonly used pharmacokinetic abbreviations
View the documentAppendix 3. Technical aspects of bioequivalence statistics
View the documentAnnex 4: Model Guidelines on Conflict of Interest and Model Proforma for a Signed Statement on Conflict of Interest
View the documentAnnex 5: Model Contract between a Regulatory Authority and an External Evaluator of Chemistry, Pharmaceutical and Bioavailability Data
View the documentAnnex 6: Model Application Form for new Marketing Authorizations, Periodic Reviews and Variations, with Notes to the Applicant
View the documentAnnex 7: Detailed Advice on Evaluation of Data by the Drug Regulatory Authority
Open this folder and view contentsAnnex 8: Ethical criteria for medicinal drug promotion1
View the documentAnnex 9: Model marketing authorization letter
View the documentAnnex 10: Model List of Variations (Changes) to Pharmaceutical Aspects of Registered Products which may be made without Prior Approval
Open this folder and view contentsAnnex 11: *Guidelines for stability testing of pharmaceutical products containing well established drug substances in conventional dosage forms1
 
13. In vitro dissolution

Comparative in vitro dissolution studies may be useful in the documentation of equivalence between two multisource pharmaceutical products. Because of many limitations associated with the use of in vitro dissolution in the documentation of equivalence this guidelines recommends that its application for this purpose be kept to a minimum. Hence, in vitro dissolution testing as the sole documentation of equivalence is not applicable to drugs that fall within the criteria of the pharmaceutical products listed on p.117 from (a) to (e). This approach should also be reserved for rapidly dissolving drug products.1 When such multisource test and reference products, both dissolve with sufficient rapidity (e.g., >80% in 15 minutes), their in vivo equivalence may be presumed. Approval of multisource formulations using comparative in vitro dissolution studies should be based on generation of comparative dissolution profiles rather than single point dissolution tests, such as are described in various compendia. Multiple dissolution test conditions and physiologically relevant media are recommended.

1 Where a drug substance and drug product do not dissolve with sufficient rapidity, as noted above, in vitro dissolution methods might still be used to document equivalence using appropriately validated dissolution methodology to include a in vitro/in vivo correlation. Such methodology should derive from development and application of specifications and statistical methods to define nonequivalence. This development may require formulations with different in vivo performance characteristics. With such formulations, discriminating in vitro dissolution tests for use in equivalence studies may be developed. With these additional requirements, however, performance of a standard in vivo bioequivalence as described in section 7 may be preferable.

to previous section to next section
 

Last updated: April 24, 2012